• <tt id="w3skg"><delect id="w3skg"></delect></tt>
      <form id="w3skg"></form>
    1. 国产九九久久99精品影院,国产原创精品巨作av,2020免费a级毛片无码,国产FREEXXXX性播放麻豆,无码毛片一区二区视频,久久精品国产精品非洲,亚洲午夜无码AV毛片久久,欧美精品久久天天躁
      Welcome to the official website of Shenzhen hongmei Technology Co.,Ltd!
    2. TaoBao
    3. China
    4. English
    5. Shenzhen hongmei Technology Co.,Ltd
      HOME ABOUT PRODUCT CASE VIDEO NEWS CONTACT
       
      PRODUCTS  CENTER
      ——   產(chǎn)品展示   ——
      Linear displacement sensor
      HLC pull rod linear displacement sensor
      KTF slide type linear displacement sensor
      KTM micro pull rod linear displacement sensor
      KTR self reset linear displacement sensor
      KPM miniature hinged linear displacement sensor
      DHL waterproof linear displacement sensor
      HPC hinged linear displacement sensor
      Transmitting module
      Displacement digital display meter
      HM-11 single channel intelligent measurement and control instrument
      HM-12 dual channel intelligent measurement and control instrument
      NEWS  CENTER
      ——   新聞中心   ——
        ·  Speed and pressure control of injec
        ·  Application of linear displacement
        ·  Displacement Sensor Used in Tool Da
        ·  The displacement sensor can be used
        ·  The necessity of linear trimming fo

      24-hour hotline
      18002573585

      Analysis and solution of analog signal interference in measurement and control system


      With the development of technology and the deep implementation of national intelligent manufacturing strategy, displacement sensor measurement and control system is widely used in the field of industrial automation. Displacement sensor used in measurement and control system is mainly used in displacement measurement, position positioning, size measurement and other occasions. The performance of the sensor can directly affect the control accuracy and use effect of mechanical equipment. Because of the strong electric circuit, electric field and magnetic field of mechanical equipment, the measurement accuracy and reliability of displacement measurement and control system are often greatly affected. How to effectively weaken or eliminate the influence of interference factors is the key point to ensure the accuracy and performance of mechanical equipment.

      There are large interference sources in the structure of industrial equipment with large variation of voltage and current. According to different interference modes, it can be divided into common mode interference and differential mode interference. Common mode interference (CMI) is the potential difference between signal and ground, which is mainly caused by the series connection of power grid, ground potential difference and common state (same direction) voltage induced by space electromagnetic radiation on signal line. The common mode voltage can be converted into differential mode voltage through asymmetric circuit, which directly affects the measurement and control signal and causes damage to components. Differential mode interference refers to the interference voltage between signal poles, which is mainly formed by coupling induction of space electromagnetic field between signals and conversion of common mode interference by unbalanced circuit. This kind of interference is directly superimposed on the signal and directly affects the measurement and control accuracy.

      What are the main interference sources of analog signal in displacement sensor measurement and control system?

      1. Radiation interference from space

      Space radiation interference is mainly produced by power network, transient process of electrical equipment, lightning, radio broadcasting, television, radar, high frequency induction heating equipment, etc. The interference intensity is related to the field equipment layout and the electromagnetic field generated by the equipment, especially the frequency, which is generally protected by shielded cables or high-voltage relief elements.

      2. Interference of system external leads

      It is mainly introduced through power supply and signal line, which is usually called conducted interference. There are both common mode interference and differential mode interference. There are many methods to suppress conducted interference, and the most effective one is to use passive filter.

      3. Power interference

      It is common that the displacement measurement and control system fault is caused by power supply interference in industrial field. In general, the power supply of PLC system is provided by power grid. Due to the wide coverage of power grid, it will be subject to all space electromagnetic interference and the change of internal voltage of power grid. PLC system usually uses isolated power supply, but its isolation performance is not ideal due to the influence of structure design and manufacturing process.

      4. Interference of grounding system in disorder

      Grounding is a common and effective means to improve the electromagnetic compatibility of electronic equipment. Correct grounding can not only restrain the influence of electromagnetic interference, but also restrain the equipment from sending out interference; while wrong grounding will lead to serious interference signal.

      5. Interference from PLC system

      The mutual electromagnetic radiation between components and circuits in the system will cause interference, so the PLC system should give priority to the products with good field application performance.

      How to solve the signal interference of PLC system effectively?

      The ideal state is to select equipment with better isolation performance, select high-quality power supply, power line and signal line, and reasonable wiring and grounding. However, this requires the cooperation of different equipment manufacturers, and the cost is high. More on-site will consider using various methods to do a good job in signal isolation and filtering, to reduce the impact of interference signal on the system. The common treatment methods are as follows:

      Add signal isolator;

      Add magnetic ring and capacitance;

      PLC power supply and isolation transformer;

      Switch value, analog signal and digital signal go separately;

      The current signal transmission is adopted to improve the anti-interference ability of the system;

      PLC input and output signal line needs to use shielding wire, which is suspended at the input and output side and grounded at the PLC side;

      The signal line should be far away from strong interference sources, such as frequency converter, high-power silicon rectifier and large power equipment;

      The shielding layer of twisted pair shielded wire should be grounded at both ends, but if there is potential difference between the two ends of the cable, the connection current will be generated in the shielding layer. At this time, one end of the cable shielding layer should be grounded.





    6. previous:Speed and pressure control of injection molding machine base
    7. next:What are the main factors of signal delay in displacement se
    8.  
      Company number: 0755-27680086
      Fax: 0755-23403882
      Email: 2048531578@qq.com
      Address: 703, Xinan culture building, Shangcun community, Gongming street, Guangming New District, Shenzhen, Guangdong Province Production base: No.15 xinyongda Road, Dongguan City, Guangdong Province
       
       
      Shenzhen hongmei Technology Co.,Ltd  copyright    Record No:粵ICP備18118559號(hào)-1  
      主站蜘蛛池模板: 高潮网站一区二区在线观看| 大香蕉视频精品在线| 国产成人r级在线视频| 亚洲av二区三区在线| 四虎影视永久地址WWW成人| 国产熟妇高潮呻吟喷水| 无码人妻丰满熟妇啪啪| 我在ktv被六个男人玩一晚上| 久久亚洲精品国产精品| 日本高清乱码中文字幕| 久久亚洲色WWW成人男男| 久久久久国产精品区片区无码 | 色综合天天综合网无码| 一级毛片在线播放| 2021韩国午夜福利片在线观看| 日本精品一区二区三区高清| 人妻少妇精品视频一区二区三区 | 野花日本高清在线观看免费| 国语国产自产精品| 芈月传在线观看免费全集| 国产精品色哟哟| 国产精品一级片| 大香一本蕉伊线亚洲网日日更新 | 亚洲国产一区二区三区在线观看 | freesexvideos张柏芝| 肃宁县| 99热精品久久只有精品| 国产AV一区二区三区人妻| 论坛| 国产婷婷精品av在线| 国产真实老熟女无套| 狠狠色色综合网站| 欢迎访问欧美日韩国产一区二区三区不卡 | 久久久久久精品毛片a级蜜桃| 国产精品午夜福利91| AAAA性BBBB欧美| 人妻少妇偷人精品无码| 99久久久无码国产精品试看| 晋宁县| 免费视频一区二区三区| 久久国产精品网|